Home > Event Id > Event Id 11 The Driver Detected A Controller Error On Device Harddisk1 Dr1

Event Id 11 The Driver Detected A Controller Error On Device Harddisk1 Dr1

Contents

http://forums.anandtech.com/showthread.php?t=2237591 In my case it seems that problem was not in cables, but in the faulty motherboard SATA port. My Windows Server Backup is scheduled at 9:00PM daily. RAID arrays can fail. Once in a while, the drive has trouble waking up and generate this controller error. have a peek at this web-site

Still, going forward this should improve things, I'll report back on that. However, I should have mentioned that I had scanned those kbs, but dismissed them as I don't have SCSI, RAID or Clusters. By creating an account, you're agreeing to our Terms of Use, Privacy Policy and to receive emails from Spiceworks. From a newsgroup post: "I had the same error on my MSI board, 1700 AMD XP, 512mb Ram, 2 hard drives each partitioned at 20x20, and Windows 2000 Advanced Server.

Event Id 11 The Driver Detected A Controller Error On Device Harddisk1 Dr1

The most prominent omission from your valuable contribution is the Microsoft troubleshooter. Under there you will have several nodes for "Harddisk0" ... Well, you have to figure things like spin-up and seek are going to vary disk to disk according to circumstances, so maybe some operations take longer or have retries on one mounted.doc 0 Message Author Comment by:Jsmply ID: 331208222010-07-01 Okay, please see the above post also.

I had assumed the issue was because it got stuck in sleep mode. x 275 Corey Monteiro Boot-up was also very slow when these errors began to occur. However, like I said earlier, it does on occasion occur during the day at a random time. Event Id 11 Windows 7 The system itself is a brand new install of Windows 7, and the diagnostics have been run on the system and it seems to be running flawlessly and with the latest

Disregard the error? (why not, my backups are ok...) Is the disk or controller is about to fail? To solve the error, a full SMART scan with repair (reallocation of unstable sectors) should be performed. I then removed the "Remote Storage Service". Noxcho/Ocanada, do you think the repartition/format is neccesary if its fixed?

Cheers, Derek Reply Subscribe RELATED TOPICS: How to determine what physical disk this error is referring to? Event Id 11 Wininit And sure the event log was giving various errors. 0 LVL 46 Overall: Level 46 Storage Hardware 30 Windows 7 16 Hardware 11 Message Active today Expert Comment by:noxcho ID: It's always around 9 or 10 AM and that's when the error is occurring. 0 LVL 46 Overall: Level 46 Storage Hardware 30 Windows 7 16 Hardware 11 Message There are many motherboards starting at just $50 and in most cases it will improve overall performance and stability for you, even if you keep the same CPU and other components.

Event Id 11 Disk Controller Error

I have never heard of such a thing, but perhaps it does exist out there somewhere. How to prove that gcd(m+1, n+1) divides (mn-1) How to tell my parents I want to marry my girlfriend How to make use of Devel debugging functions on large or complex Event Id 11 The Driver Detected A Controller Error On Device Harddisk1 Dr1 This will be demonstrated using Windows… Windows 7 Advertise Here 656 members asked questions and received personalized solutions in the past 7 days. Event Id 11 Atapi Event ID 11 - which hard drive has problem???

TheEventId.Net for Splunk Add-onassumes thatSplunkis collecting information from Windows servers and workstation via the Splunk Universal Forwarder. Check This Out Is "DR2" = "Disk 2"? x 267 Paol In my case, there problem was the power source. After lots of drive and cable swapping I have discovered it happens because I have the drive caddy plugged into a Noontec USB3 hub. Event Id 11 Disk The Driver Detected A Controller Error

This will let you remove BESR from suspicious list. 0 Message Author Comment by:Jsmply ID: 331259692010-07-02 Well we tried a fresh install of Windows 7 recently, that did not help. Ended up saying they have no further ideas and were willing to ship a new MOBO if we want. One 1040b's scsi id is 6, and the other is 7. http://justjoomla.net/event-id/event-id-129-reset-to-device-device-raidport0-was-issued.html I knew it had to be a hardware issue because i had Win7 running fine for a few years.

I reviewed all connections, they seemed fine. Event Id 11 Custom Dynamic Link Libraries Specifically we don't get the "IO_ERR_CONTROLLER_ERROR" part of the message or the 1% at the end of the controller message. One more thing - best not to operate the computer if it overheats.

If it's something hidden in the protected space of the kernel then outside processes likely cannot inquire against it, and they can't very well wait for the kernel to stop can

Then I can resume that this error is just your system reaction to drive removal. http://support.microsoft.com/kb/159865 NOTE: Disk Management is enhanced in Windows 2000 and later operating systems. Join them; it only takes a minute: Sign up Here's how it works: Anybody can ask a question Anybody can answer The best answers are voted up and rise to the Event Id 11 Server 2008 R2 Nothing shows up under that process ID.

Maybe Windows Backup build in a temp local folder an "image" of the backup (around 40GB), and when it's complete, around 9:30PM, send it to the USB drive. To "truly" solve this, you'd likely have to install the debugging version of windows and put windows into step-by-step debugging mode and might have to have the debugging code of the I will follow the suggestions here to see what happens Kevin Mar 06, 2012 @ 17:23:24 I have been dealing with this same problem and have checked everything and I to have a peek here for my IDE drive the problem has not appeared anymore.

Checking the event viewer reveals it's been going on for 3 months. We shall see if its the final answer or not. It seems that the jumper setting from my IDE drive, which worked with my old power supply, wouldn't do so with the new supply. There are also also 3 more similar messages for Harddisk 2, 4, and 5, but not zero or 1.

also check for any drive issues in device manager. my perception is that this has been a long term failure in the management of the Microsoft development process, or to phrase it another way, nobody has a clue WTF is If you are into free software on Linux, like several commenters were, I would recommend ZFS, which is part of an excellent FreeBSD distribution. not very reassuring. 0 LVL 11 Overall: Level 11 Storage Hardware 7 Hardware 3 Windows 7 3 Message Expert Comment by:ocanada_techguy ID: 331278052010-07-02 Honestly, I'm "reaching" and guessing too.

cue Fred Flinstone "friger frickin... The hardware problems can be associated with poor cabling, incorrect termination or transfer rate settings, lazy or slow device responses to relinquish the SCSI bus, a faulty device, or, in very Maybe it's a combination of windows and drivers and hardware sort of timing-out that all just happen to coincide. IE: \Device\HardDisk1\DR5, then the error can be shown with \Device\HardDisk1\DR1, and then \Device\HardDisk1\DR2, etc.

Generated Mon, 09 Jan 2017 03:18:42 GMT by s_hp81 (squid/3.5.20) ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.2/ Connection Bitte versuchen Sie es später erneut. more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed At first, I thought it was just a hardware problem with the system I got, but it's replacement suffered from the same thing.

Which means, don't see BESR causing it. What was causing the errors happened to be the hard drive carrier. Thanks! Log Name: System Source: Disk Event ID: 11 Task Category: None Level: Error Keywords: Classic User: N/A Computer: PC1 Description: The Does it mean that since reinit you do not get the Event 11 anymore? 0 Message Author Comment by:Jsmply ID: 331168472010-07-01 No, what I meant was, when doing a safely

Start - type regedit - enter. Logged Units I own: TS-XL, TS-WXL, LS-WVL, TS-RXL, TS5400, TS-RVHL,I don't work for Buffalo but i do love there products enough to help people fdlwebmaster Calf Posts: 5 Re: EventID 11 One more drive in the rotation to change (tomorrow) and hopefully they will remain problem free.